Journal of System Simulation ›› 2015, Vol. 27 ›› Issue (5): 1152-1157.

Previous Articles    

PID Closed Loop Control Performance Analysis of Piezostack-driven Jet Dispensing Valve

Fu Yunbo1, Li Xinbo1, Liu Guojun2, Liu Jianfang2, Shi Yaowu1   

  1. 1. School of Communication Engineering, Jilin University, Changchun 130022, China;
    2. School of Mechanical Science and Engineering, Jilin University, Changchun 130022, China
  • Received:2014-05-03 Revised:2014-10-28 Online:2015-05-08 Published:2020-09-01

Abstract: A new type of piezostack-driven jetting dispenser was proposed which used hydraulic magnification, and analyzed its injection process and injection condition. The open loop model of dispensing system was built by AMESim software. The simulation proved the feasibility. The closed loop control system with PID (Proportion Integration Differentiation) algorithm was set up to improve performance of open loop dispensing system, and the open and closed loop control performance was compared under the simulation environment. Analysis shows that PID closed loop system can improve performance of piezostack-driven jetting dispensing system. When nozzle diameter is 0.1mm and syringe pressure is 8 bar, by closed loop control, the achieved average flow rate is 0.023L/min and the minimum diameter of stable droplets is 0.8 mm.

Key words: piezoelectric driven, AMESim simulation, jet dispensing, hydraulic magnification

CLC Number: