Journal of System Simulation ›› 2017, Vol. 29 ›› Issue (5): 1033-1040.doi: 10.16182/j.issn1004731x.joss.201705014

Previous Articles     Next Articles

Study on Effect of Neglecting Transient Terms of Momentum Equations on Simulation Models of Single Phase Heated Tubes

Kang Yingwei1,2, Wang Yanan1,2, Peng Daogang1,2, Zheng Pengyuan1,2, Yang Ping1,2   

  1. 1. College of Automation Engineering, Shanghai University of Electric Power, Shanghai 200090, China;
    2. Shanghai Engineering Research Center of Intelligent Management and Control for Power Process, Shanghai 200090, China
  • Received:2015-07-06 Revised:2015-09-24 Online:2017-05-08 Published:2020-06-03

Abstract: A model of single phase heated tubes was presented, based on which the effect of neglecting transient terms of momentum equations on model performance was investigated by simulating a heated tube of the superheater of a power plant boiler. It is found that neglecting the transient terms of momentum equations can significantly decrease the dynamic accuracy of the model; under various step disturbances, neglecting the transient terms of momentum equations can speed up the dynamic response of the enthalpy-temperature channel of the model nearly 4 times; under the step disturbance of the inlet steam flux, neglecting the transient terms of momentum equations can change the type of dynamic characteristics of the pressure-flow channel of the model; whereas the corresponding decrease of computational consuming time is less than 7%; moreover, the ability to keep numerically stable also decreases.

Key words: single phase heated tube, superheater, simulation model, momentum equation, transient term

CLC Number: