Temperature Field Simulation Analysis of Common Rail Injector Based on Multi-Field Coupling

Chen Yutao1, Wang Zuoqun2, Long Zhengwei3, Zhang Mingrui1, An Qingsong1,*, Chen Guibing1   

  1. 1. Key Laboratory of Efficient Utilization of Low and Medium Grade Energy, Ministry of Education, Tianjin University, Tianjin 300350, China;
    2. Shanghai Marine Diesel Engine Research Institute, Shanghai 200072, China;
    3. School of Environmental Science and Engineering, Tianjin University, Tianjin 300350, China
  • Received:2017-05-27 Revised:2017-08-28 Published:2019-12-12

Abstract: The reliability of high pressure common rail injector depends on the calculation accuracy of its temperature changing. Due to the temperature measurement limitation and difficulty, in order to obtain more detailed temperature distribution, a coupling physical model is established in this paper based on multi-fields coupling analysis method, and a method based on the uni-directional coupling for calculating the temperature distribution of injector accurately is developed. The results show that the convective heat transfer coefficient varies with the flow state and the multi-field coupling method can correct the convective heat transfer coefficient according to the flow state automatically, which improves the prediction accuracy of the actual temperature distribution of the injector and provides a common solution frame for similar fluid-solid coupling problems.

Key words: marine high-pressure common rail injector, temperature field, three-dimensional simulation, unidirectional fluid-structure coupling